Bay Heating & Air Conditioning has been servicing the heating and air conditioning needs of Cleveland OH since 1944.

Call us now at: 440-249-0500 or check out the reviews and testimonials from your neighbors, that make us the top rated service provider in Cleveland OH.

Local Reviews
for Cleveland, OH

Bay Furnace Rated 5.0 out of 5 stars based on 81 customer reviews


Exceptional Service, always informs what is going to be done




Review of Bay Furnace

Jose Montes is always on time and very courteous. Makes sure I understand what needs to be checked and also shows me what he has done when he has completed the job.


Great service




Review of Bay Furnace

Jose is fantastic


A/C tuneup! Nice polite service!




Review of Bay Furnace

On time and very polite. Performed a thorough cleaning and checkup


great service and tech




Review of Bay Furnace

great company, you are my HVAC people thanks mike fridrich president fridrich moving


Fantastic




Review of Bay Furnace


Excellent Service, Very Professional, Super Courteous




Review of Bay Furnace

Jose arrived on time and explained what needed to be done and checked on my furnace unit, he then got to work and he welcomed the questions that I had.I appreciate the attention to detail


great guy




Review of Bay Furnace

great guy. hang onto him


Great Service




Review of Bay Furnace

Marty took care of everything. Looked everything over and cleaned everything and was able to answer any questions I had.


great fixing of problem




Review of Bay Furnace


Competent and friendly service




Review of Bay Furnace

Jason arrived as scheduled, got right on the problem, and was able to overcome any difficulties he encountered. He patiently answered any questions that I had and was pleasant in his demeanor.


Super Service




Review of Bay Furnace

Efficient detailed furnace cleaning service


Great service very plesant




Review of Bay Furnace

Jose is very helpful and informs u what he is doing


Mr




Review of Bay Furnace


Great company




Review of Bay Furnace

Marty arrived on-time, went right to work, found the problem, Fixed it and was done very quickly.


always good




Review of Bay Furnace

never a doubt with Jose


Besham B.

Besham B.

Check thermostat check blower motor checked filter customer supply flush condensate drain. Supply air 54* return air 71*. Check disconnect check capacitor 40+5 +440. Cycle unit on to check compressor and fan motor working. Wash and clean condenser coil. Outdoor temperature is 88*. At times of dispatch unit is working.

Near W 57th St, Cleveland, OH 44102
Cory B.

Cory B.

Selling house - needed estimate for house

Near W 130th St, Cleveland, OH 44111
Jason J.

Jason J.

Leak search. I used an electronica leak detector and checked the inside and outside of the condenser and evaporator coil. I inspected all braze joints And could not find any definitive leaks.

Near W 165th St, Cleveland, OH 44111
Jose M.

Jose M.

Club A/C Tuneup. Replace #410Sg. T-Stat, 70*-54*=16* D-T, Blower Motor, Bypass Humidifier Turn Off And Damper Close, Blower Motor, R410A, Disconnect, 2= Amps Fuse, Electrical, 45+5+440 Dual Run Cap, Hose Down, 79* Outside, Remove Leaves And Cottonwood, Cycled Unit, Clean And Check.

Near Woodhaven Ave, Cleveland, OH 44144
Jason J.

Jason J.

No cooling. Upon arrival I inspected and replaced the filter with the customers supply. I checked condenser. I checked pressures and found system was low on refrigerant. I added 3 lbs. 9 oz. of R- 410 A to bring system to 14° of sub cooling. System is operational at this time. I highly recommend scheduling a leak search of the system.

Near W 165th St, Cleveland, OH 44111
Jose M.

Jose M.

Club A/C Tuneup. Replace Digital Non Programmable T-Stat. #16x25x1 Air Filter, Drain Trap, 76*-60*=16* D-T, Blower Motor, R-22, Disconnect, 35+5+370 Dual Run Cap, Electrical, 68* Outside, Hose Down, Remove Leaves And Cottonwood, Cycled Unit, Clean And Check.

Near Puritas Ave, Cleveland, OH 44135
Marty T.

Marty T.

Cycle Matt Litzler s unit several times check refrigerant charge checked contactor capacitor compressor and fan unit operating properly at this time

Near W 160th St, Cleveland, OH 44135
Brian M.

Brian M.

Found System low on refrigerant. Also found outdoor unit dirty. Cleansed off outdoor unit with hose and water. Added 6 pounds are 22. Cycled system to check. System is operating properly at this time. Thanks Brian.

Near Flamingo Ave, Cleveland, OH 44135
Marty T.

Marty T.

Found air conditioner compressor shorted to ground both fuses blown oversized fuses were 30 Amp. maximum fuse for air-conditioner is 20 remove top to verify compressor was indeed bad and it is unit must be replaced

Near W 145th St, Cleveland, OH 44135
Marty M.

Marty M.

Ductwork

Near Albers Ave, Cleveland, OH 44111
Besham B.

Besham B.

Check thermostat check blower motor change filter customer supply flush condensate drain and check condensate pump working. Supply air 42 return air 65*. Check disconnect check capacitor 35+5+440 Dual Run Cap. Cycle unit on to check compressor and fan motor working. Wash and clean condenser coil. Outdoor temperature is 81*. At times of dispatch unit is working.

Near Melgrave Ave, Cleveland, OH 44135
Jose M.

Jose M.

Club A/C Tuneup. T-Stat, #16x25x1 Air Filter, Drain Trap And Pump, 71*-51*=20*D-T, Blower Motor, R-22, Disconnect, 2=30 Amps Fuse Electrical, 45+5+440 Dual Run Cap, 65* & Heavy Rain Outside, Cycled Unit, Clean And Check.

Near W 90th St, Cleveland, OH 44102
Jose M.

Jose M.

Club A/C Tuneup. Replace #410Sg. T-Stat, 70*-50*=20*D-T, Drain Trap, Blower Motor, R-22, Disconnect, 2=50 Amps Fuse, Electrical, 50+5+370 Dual Run Cap, 72* Outside, Hose Down, Cycled Unit Clean And Check.

Near Bader Ave, Cleveland, OH 44109
Jose M.

Jose M.

Club A/C Tuneup. T-Stat, #16x25x1 Air Filter, Drain Trap, Bypass Humidifier Turn Off And Damper Close, Blower Motor, R410A, Disconnect, 55+7.5+370 Dual Run Cap, Electrical, 64* Outside, Remove Leaves And Cottonwood, Hose Down, Cycled Unit Clean And Check. Inducer Making Noise, Inducer Assembly $1062.00

Near Norway Ave, Cleveland, OH 44111
Jason J.

Jason J.

Unit freezing up. This is an installation done by another company. I found the reason for the evaporator coil freezing was 1/3 of the coil was blocked with a piece of sheet metal. It was blocking the far right side of the evaporator coil. I remove the sheet metal and check charge I found the system was low on charge from install. I added 2 pounds of refrigerant 410A and cycled the system with 10° of sub cooling. System is operating properly at this time.

Near Valleyview Ave, Cleveland, OH 44135
TJ G.

TJ G.

A/C tuneup complete, flushed drain, filter was clean, turned bypass humidifier off for season, hosed down condenser coil, checked capacitor/compressor/contacter, all electrical connections are secure, cycled cooling with ok operation.

Near Elmore Ave, Cleveland, OH 44126
Besham B.

Besham B.

Check Thermostat check blower motor check filter recommend filter change customer said he will change it. Flush condensate drain turn Humidifier off. Supply air 50*return air 70*. Check disconnect 30 amps Fuse. Check capacitor 50+5+440 Dual Run Cap. Cycled unit on the check compressor and fan working. Wash and clean condenser coil. Outdoor temperature 66°. At time of dispatch unit is working.

Near W 145th St, Cleveland, OH 44135
Jose M.

Jose M.

Club A/C Tuneup. T-Stat, #401Sg, Drain Trap And Pump, 66*-50*=16* D-T, Blower Motor, R410A, Disconnect, 2=20 Amps Fuse, Electrical, 35+5+440 Dual Run Cap, 71* & Rain, Cycled Unit Clean And Check.

Near W 158th St, Cleveland, OH 44135
Besham B.

Besham B.

Check thermostat check filter customer supply check blower motor flush condensate drain. Supply air 42* return air 64*. Check disconnect 30 amp fuse. Check capacitor 45+5+440 Dual Run Cap. Cycled unit on to check compressor and fan Working. Wash and clean condenser coil. Outdoor temperature 72°. At times of dispatch unit is working.

Near W 102nd St, Cleveland, OH 44102
Jose M.

Jose M.

$119.95 A/C Tuneup. Found A Bad T-Stat And Plug Air Filter. Replace Both Cycled Unit Fine At This Time.

Near W 136th St, Cleveland, OH 44111
Jason J.

Jason J.

Club A/C Tuneup. Replace #401Sg. T-Stat, Drain Trap, Blower Motor, R410A, Disconnect, 45+5+440 Dual Run Cap, Electrical, 57* Outside, (Jason) I arrived and checked thermostat wiring. I switched the humidifier and dehumm wiring. I cycled the system with proper operation.

Near Bradgate Ave, Cleveland, OH 44111
TJ G.

TJ G.

Cycled system from stat, ok Changed filter Flushed condensation drain. Inspected outdoor and capacitor, all within spec. Could not wash.

Near Longmead Ave, Cleveland, OH 44135
Marty T.

Marty T.

Found both units disconnects reversed reinstall check first floor unit OK second-floor unit slightly low on refrigerant Adjust superheat Cory giving estimates this day replacement for second floor needs serious consideration

Near Lake Ave, Cleveland, OH 44102
Jose M.

Jose M.

$119.95 A/C Tuneup. T-Stat, #413Sg, Drain Trap, 70*-54*=16* D-T, Blower Motor, R410A, Disconnect, 2=25 Amps Fuse, Electrical, 35+5+440 Dual Run Cap, 64* Outside, Hose Down, Remove Leaves And Cottonwood, Cycled Unit Clean And Check.

Near Parkmount Ave, Cleveland, OH 44135
Brian M.

Brian M.

Checked Checked both thermostats. Checked both batteries in thermostat. Checked both filters. Customer changes the filters themselves. Flushed out both condensate pumps with bleach and water. Checked all electrical connections. Checked capacitors. Checked contactors. Cleaned both outdoor condensing coils with water. Both systems are operating properly at this time. Thanks Brian