Bay Heating & Air Conditioning has been servicing the heating and air conditioning needs of Fairview Park OH since 1944.

Call us now at: 440-249-0500 or check out the reviews and testimonials from your neighbors, that make us the top rated service provider in Fairview Park OH.

Local Reviews
for Fairview Park, OH

Bay Furnace Rated 5.0 out of 5 stars based on 90 customer reviews


Arrived on time and did a great job.




Review of Bay Furnace

Technician did a great job. I appreciated him arriving on time. All good.


Excellent and friendly service.




Review of Bay Furnace

My experience with your technician was an absolute please. Was on time, cordially greeted us and answered all our questions.


Great service




Review of Bay Furnace


We always get great service .




Review of Bay Furnace

Marty, gives us the best service always and explains what he is doing.He is a great service man.


Great




Review of Bay Furnace


Jose Montes did a Great Job!!!




Review of Bay Furnace

We truly appreciated the great service we received from Jose Montes ... He spent time going over what he would be doing as well as offering us Bay Furnace Club Membership which we did sign up for and were very happy with the savings on our service call ... Thank you!!


Prompt courteous service from first call to office to excellent service call




Review of Bay Furnace

I cannot say enough about all the wonderful service I have had over many years. Kim always is so helpful and Marty has always had my complete confidence in so many ways. Always explains everything and gets problems solved with his great knowledge and courteous manner. I can t imagine calling anywhere else. Thank you Kim and Marty for being there. I truly appreciate you both.


Great service.




Review of Bay Furnace


Annual Furnace Cleaning




Review of Bay Furnace


all good, as always




Review of Bay Furnace

always great, fast, efficient and 'put the customer first' service from the Bay Furnace techs


Exceeded expectations...




Review of Bay Furnace


Great Service




Review of Bay Furnace

We have been customers of Bay Furnace for many years now and they are truly professional with the work they do and just good people you can welcome into your home!!


Excellent service




Review of Bay Furnace

The fault wouldn't show up no matter what he tried so I'm relieved I didna't have to replace the fan motor. Jason showed awesome knowledge of the furnace. I was highly impressed with his expertise.


Great service.




Review of Bay Furnace


Jason was great. Office very helpful when we forgot our appointment.




Review of Bay Furnace


TJ G.

TJ G.

3 A/c tuneups complete, flushed drains, 201 filters were clean/coustomer supplied, turned all three fan powered humidifiers off for the season, hosed Down condenser coils, checked capacitors/contacters/compressors, all electrical connections secure, cycled cooling with ok operation.

Near N Valley Dr, Fairview Park, OH 44126
Brian M.

Brian M.

Check thermostat. Checked AC drain. Flushed AC drain with water. Checked filter. Change filter supplied by customer. Checked all electrical connections. Checked contactor. Checked capacitor. Cleaned outdoor condensing coil with water. Cycled heating system. Cleaned flame sensor. Flushed heating trap. Checked amp price. Checked amp draw on blower motor. Cycled system to check. System is operating properly at this time. Thanks Brian

Near W 225th St, Fairview Park, OH 44126
TJ G.

TJ G.

A/C tuneup, flushed condensation drain, replaced customer provided filter, leveled A/C unit with gravel, checked capacitor/contacter and amp draw, washed unit, checked electrical connections, cycled unit ok operation

Near Westwood Rd, Fairview Park, OH 44126
Marty T.

Marty T.

Found two air-conditioners contact customer got his voicemail unsure of which one was not working both working on my arrival only problem found was bug partially under contactor on first floor unit removed cycled both to check. Units icing up slightly found both units low on refrigerant added 1 pound each unit is 20 years old replacement needs serious consideration due to age . Downstairs units compressor making funny noise indicating bearings going bad

Near N Valley Dr, Fairview Park, OH 44126
TJ G.

TJ G.

A/C tuneup complete, replaced filters and flushed drain, checked contacter, fan and compressor, all connection secure, cycled cooling from T-stat

Near N Valley Dr, Fairview Park, OH 44126
Jose M.

Jose M.

Club A/C Tuneup. Owner Will Replace #16x25x4 Air Filter. T-Stat, Drain Trap, Fan Power Humidifier Turn Off, Blower Motor, R-22, Disconnect, 2=25 Amps Fuse, Electrical, 35+5+370 Dual Run Cap, 58* Outside, No Water Outside, Cycled Unit Clean And Check.

Near Lorain Rd, Fairview Park, OH 44126
TJ G.

TJ G.

Cycled system from tstat, all within spec Reset tstat Checked filter, did not need changed yet Flushed condensation drain and pump Inspected outdoor unit and capacitor, all within spec Washed outdoor unit

Near Stanford Ave, Fairview Park, OH 44126
Jose M.

Jose M.

Furnace Making Noise. At My Arrival customer states unit makes noise on heating mode checked inducer checked blower motor tighten all the screws no noise at this time .

Near W 220th St, Fairview Park, OH 44126
Brian M.

Brian M.

. Found inducer motor to be making a squealing noise. Quoted customer on replacing inducer motor. Also gave customer three options at replacing system. System is from 1998 and 21 years old. I explain to her that we do not recommend putting a $680 repair onto a 21-year-old system. Customer would like a little time to review her options. And will get back to us tomorrow with her decision. Thanks Brian

Near W 226th St, Fairview Park, OH 44126
Besham B.

Besham B.

Check t/start change filter flush condensate drain check blower motor. Checked disconnect check capacitor 50+440run cap 10+370 run cap. Check contactor cycle unit to check compressor and fan motor working. Wash and clean condenser coil. Outdoor temperature 46*. At times of dispatch unit is working.

Near Saratoga Dr, Fairview Park, OH 44126
Jose M.

Jose M.

Club A/C Tuneup. Found Breaker Off To Condenser Unit Reset. T-Stat, Ez-Flex #16, Drain Trap And Pump, Bypass Humidifier Turn Off And Damper Close, 66*-51*=15* D.T. Blower Motor, R410A, Electrical, 2=25 Amps,40+5+370 Dual Run Cap, Cycled Unit Clean And Check

Near W 224th St, Fairview Park, OH 44126
Marty T.

Marty T.

Clear condensate drain checked blower motor and filter checked contactor capacitor compressor and fan cycle air-conditioning to check unit older but operating well

Near Mastick Rd, Fairview Park, OH 44126
TJ G.

TJ G.

Cycled system from tstat, all within spec Flushed drain Checked filter, did not need changed Inspected outdoor unit and capacitor, all within spec Washed outdoor unit.

Near Westwood Rd, Fairview Park, OH 44126
Brian M.

Brian M.

Checked thermostat. Checked thermostat batteries. Customer explained they change the batteries themselves. Checked air filter. Customer also changes air filter themselves. Checked flame sensor. Cleaned flame sensor. Checked inducer motor amp draw checked blower motor amp draw checked and measured gas pressure also check temperature rise. Zero ppm carbon monoxide in the airstream at this time. Cleaned out inside of return air trunk. Also wipe down and clean the entire inside of the furnace due to construction dust. Cycled system to check. System is operating properly at this time. Thanks Brian

Near W 224th St, Fairview Park, OH 44126
Besham B.

Besham B.

Check t/start flushed condensate drain check filter .Recommend filtered to change customer did not want to change until one year was told filter last for one year. Check condensate pump working. Check disconnect two 30 amp fuse . Check capacitor 40+5 Dual Run Cap readings were 38+5 amps. Bump start unit to check compressor and fan motor working. Wash and clean condenser coil. Outdoor temperature is 46*. At time of dispatch unit is working.

Near Eastwood Ave, Fairview Park, OH 44126
Brian M.

Brian M.

check the thermostat. Checked filter. Flushed AC trap with water. And bleach. Flushed out outdoor coil with hose and water. Checked capacitor. Capacitor is -6% capacity customer believes he can fix it himself. Declined a quote at this time. Checked contactor checked all electrical connections cycled system system has a 17° temp drop. Thanks Brian

Near W 219th St, Fairview Park, OH 44126
TJ G.

TJ G.

Checked tstat, ok Tested blowe, ok Flushed drain Shut down humidifier for season Inspected outdoor unit and capacitor, ok Washed outdoor unit.

Near S Park Dr, Fairview Park, OH 44126
Jose M.

Jose M.

$119.95 A/C Tuneup. (No Water Outside Broken Water Line). T-Stat, #16x25x1 Air Filter, Drain Trap, Fan Power Humidifier Turn Off, Blower Motor, R410A, Disconnect, 45+5+440 Dual Run Cap, Electrical, 43* & Rain Outside, Bump Start, Clean And Check.

Near Robinhood Ave, Fairview Park, OH 44126
TJ G.

TJ G.

Checked tstat,ok Cycled cooling, operational Checked filter, ok Plus he drain and cleared pump Tested outdoor Cap, ok Washed and scrubbed outdoor unit.

Near Woodstock Ave, Fairview Park, OH 44126
Jason J.

Jason J.

Air-conditioning tuneup (x2). Condenser coil‘s were washed out. Contactors, capacitors and connections were inspected. Condensate traps were flushed out. Media filters were replaced. Both systems were cycled with normal operation.

Near Canyon Rd, Fairview Park, OH 44126
Jose M.

Jose M.

$119.95 Furnace Tuneup. T-Stat, 100 Ohms HSI, 80% Inducer, Flame Sensor, 3.5” W.C. Smart Gas Valve, #20x25x1 Air Filter, Blower Motor, 60* Outside Cycled Unit, Clean And Check.

Near W 220th St, Fairview Park, OH 44126
Brian M.

Brian M.

Checked thermostats. Flushed out the traps. Checked all electrical connections. Checked both capacitors. Checked both contactors. Checked both filters. Downstairs system required a new easy flex 20. Upstairs filter was good I did not need to be changed at this time. Cycle ball systems to check. Downstairs has a 23° temperature drop. Upstairs has a 12° temperature drop. Customer has explained that they have added our 22 every year to keep the upstairs system running. This is evidence of a leak Due to the age and condition of Equipment my strongest recommendation is to replace the system At this time. Thanks Brian. both systems are operating upstairs is Operating Inefficiently.

Near N Sagamore Rd, Fairview Park, OH 44126
Jose M.

Jose M.

Club A/C Tuneup. T-Stat, Drain Trap, #413Sg, V.S. Blower Motor, R410A, Disconnect, 2=40 Amps Fuse, Electrical, 45+5+440 Dual Run Cap, Hose Down, 72* And Heavy Rain, Cycled Unit, Clean And Check.

Near Parkedge Cir, Fairview Park, OH 44126
Brian M.

Brian M.

Check thermostat and batteries in thermostat. Flushed out AC trap with water. Cleaned outdoor coil with water. Checked capacitor. Checked all electrical connections. Checked contactor. AC is from 1996 and only has a 15° temp drop on a day like today I would like to see 20 to 25° temp dropped. Customer explained that they had to add Freon at the end of last year. I gave estimate on three complete furnace and AC systems. Customer would like to get another estimate before going ahead with the decision. System is operating at this time but not at 100% capacity. Thanks Brian

Near Coffinberry Blvd, Fairview Park, OH 44126
Marty T.

Marty T.

Check blower motor and filter turn off humidifier closed bypass check contactor capacitor compressor and fan cycle air conditioner to check OK clean condenser coil and condensate trap

Near Hillsdale Ave, Fairview Park, OH 44126